yontroducción de Proyecto
Introducción del usuario:
This project is designed for our Chile client. The product water is used to feeding the boiler. Due to limited workshop area, the client requried this machine is installed into 40HQ container directly. All the internal pipelines and cable was connected well. The client only need to connect the inlet water to raw water pump and product water to pure water pipe outside the container. The raw water hardness is 171mg/L, to ensure uninterrupted product water for the boiler feeding, we adopted two softener by one working, one standby. Thus when softener generation, another softener could continuous work.
| Feed water quality: | Conductivity 1089us/cm, hardness 171mg/L |
| Calidad del agua del producto: | Conductivity 30us/cm, hardness 0.3mg/L |
| Capacidad: | 30,000LPH |
| Proceso técnico: | MMF+Water softener+RO unit+CIP |
detalles del proyecto
FECHA
Dec. 2023
CONTRATISTA
Xi'an CHIWATEC Tecnología de Tratamiento de Agua Co.,Ltd.
Galería de proyectos






SÍGANOS
¿Tiene un proyecto de tratamiento de agua con el que podamos ayudar?
* Diseño, mecanizado, instalación, puesta en marcha, personalización y servicio integral