Low pressure control JC-206

Product name:pressure control switch
Model:JC-206
Brand Name:3S
Model Number:JC-206
Max. Current:5A
Max. Voltage:380V/220V
Max. Working Pressure:6bar
Pressure range:-0.5 to 6bar
Differential range:0.6 to 4 bar
Factory setting on:2bar
Factory setting off:3bar
Max bellows pressure:16.5bar
Switch action:auto type SPDT opens High/Low
Pressure connection:1/4″ Flare nut
Weight:0.42KGs

Category:

Description

1. Brief introduction of Low pressure control JC-206

Low pressure control JC-206 pressure controls is used for either operating or protecting commercial refrigeration or air-conditioning system. They are suitable for R12, R22 and R502 refrigerants and are available copper capiliiary with either flare nut connection or with male flare. Also is widely used in RO water treatment plant. Installed before the RO high pressure water pump, when the feed water pressure is lower than the settled value, the pressure switch will shut off and the machine will be stopped in case of RO high pressure water pump running idle. After malfunction treatment, reset the pressure switch is ok.

2. Specification of Low pressure control JC-206

Pressure range:-0.5 to 6bar
Differential range:0.6 to 4bar
Factory setting:on/off =2/3bar
Max bellows pressure:16.5 bar
Switch action:Auto type SPDT opens high/low
Pressure Connection:1/4″ flare nut
Weight:0.42KG

3. Fitting method for Low pressure control JC-206

  1.  Avoid sharp bend or kinks in capillary tubing.
  2. When installing to ammonia system, please contact us.
  3. Purge all tubing and lines before connecting pressure controls.
  4. Check that control is not installed on equipment handle a load in excess of electrical rating.
  5. Coil and secure excess capillary length to avoid vibration. Allow some slack in capillary to avoid “violin string” vibration which can cause tubing to break.
  6. Do not allow capillary tubing to rub against metal surface where friction can damage capillary.
  7. Do not turn sealed screws.
  8. Controls are not to be located in area of extreme moisture, dirt or dust, or in a corrosive or or explosive atmosphere. These enviroments can shorten controls life.

4. Features of Low pressure control JC-206

Electronically automatic control
Compact and inexpensive
High reliability
Easy installation and long life

5. Model choosing

ITEMPRESSURE RANGE
JACO-2030-3KG
JACO-2060-6KG
JACO-2100-10KG
JACO-2200-20KG
JACO-2300-30KG

6. Certification:

ISO9001-2019 safety production licenseCE-certification of RO-water Filtration Drinking Plant

7. Comments from customers:

Comments From Customers

8. Package and transportation:

water Filtration Drinking Plant package and transportation

9. Finished projects:


    We will answer your email shortly!


    You may also like…

    Go to Top